top of page

Thinfilm Applications

thinfilm measurement spectroscopy

Thin Film measurements

 

Optical thickness of a coating is determined by white light interference and the pattern is translated into optical thickness through mathematical calculations. 
 
Thin film metrology involves the use of these mathematical calculations to the presence and thickness of coatings which have been deposited on a substrate material using a variety of processes. The techniques available for this measurement range from profilometry to ellipsometry, spectroscopic reflectometry and x-ray analysis. Avantes instruments and fibre optic sampling tools enable spectroscopic reflectometry measurements to support applications in a variety of industries from semiconductor to solar and optical coating measurements. Avantes thin film solutions provide low cost measurement systems for single and multi-layer thin films on a number of substrates. 

Thin Film Quality Control
Thin film deposition processes require regular monitoring and quality control particularly as new recipes are implemented and optimised in a coating facility. Typical applications require regular quality control inspection during the initial phases requiring a high speed offline measurement system to validate film thickness. Avantes thin film solutions enable high speed spot measurements which can facilitate thin film presence and thickness validation. 

Thin Film Reflectometry
Spectroscopic reflectometry involves illuminating samples with a white light (typically tungsten halogen or deuterium-halogen) at an incident angle which is normal to the sample and then measuring the reflectance and interference from the same geometry. Depending upon the nature of the coating, ultra-violet, visible or near infrared wavelength measurements may be necessary to obtain an optimum fitting of the measured curve relative to the theoretical reflectance curve. The theoretical curve is developed from a database of optical constants (n and k). The “n” value is the refractive index and “k” is the extinction coefficient. The sampling process initially involves measuring a reference uncoated substrate followed by the sample measurement using the same conditions. Characteristics about the substrate (thickness and material) are inputs for the software along with characteristics of the thin film layers (material, thickness). Reflectance spectra are captured and analysed by software algorithms which compare the measured data to theoretical calculated values derived from the database of optical constants. The software provides a calculated thickness value along with a measure of goodness of fit relative to the theoretical curve.

Single-layer Thin Film Metrology
Avantes single layer thin film metrology system consists of our AvaSpec-ULS2048-USB2 fibre optic spectrometer, AvaLight-DHc/AvaLight-DH-S deuterium-halogen light source or AvaLight-HAL tungsten halogen light source, the FCR-7UV200-2-ME (optionally FCR-7UV400-2-ME for higher throughput) fibre ptic reflection probe and our Thin Film Stage. The software that drives the single layer system is AvaSoft-Thinfilm which is a 32 or 64-bit application which supports single layer measurements of thin films ranging from 10 nm-50 µm with 1nm resolution. AvaSoft-ThinFilm supports UV/VIS and NIR wavelength measurements from 200-1100nm. The system is available with an optional thin film standard which provides samples of uncoated and coated substrates for validation purposes. For most specular surface UV measurements, the AvaLight-DHc compact deuterium halogen source is adequate, but for more diffuse coated surfaces, the higher power AvaLight-DH-S is recommended. 

Multi-layer Thin Film Metrology
Avantes multi layer thin film metrology system consists of our AvaSpec-ULS2048-USB2 fibre optic spectrometer, AvaLight-DHc/AvaLight-DH-S deuterium halogen light source or AvaLight-HAL tungsten halogen light source, the FCR-7UV200-2-ME (optionally FCR-7UV400-2-ME for higher throughput) fibre optic reflection probe and our Thin Film Stage. The software which drives the multi-layer system is TFProbe 2.0 which is developed by Angstrom Sun Technologies and is fully compatible with Avantes spectrometers. This sophisticated application supports up to five layer measurements and supports a variety of methods including nk constants, dispersion, and effective media approximation (EMA). TFProbe provides a user friendly graphical user interface to input layer structure parameters. The system can include an optional thinfilm standard which provides sample uncoated and coated substrates for validation purposes. TFProbe supports UV/VIS and NIR wavelengths from 200-1700nm and enables the connection of multiple spectrometers to support this broadband wavelength measurement capability.

 

For most specular surface UV measurements, the AvaLight-DHc compact deuterium halogen source is adequate, but for more diffuse coated surfaces, the higher power AvaLight-DH-S is recommended.

AvaThinfilm System
bottom of page